How to test alarms on day one of a tenancy

4 min read

Part of: Rental inventory checklist

Short answer: in England, a landlord must make sure every required smoke and carbon monoxide alarm is in proper working order on the day a new tenancy begins. On that day, test each alarm, photograph it with its replacement date visible, and record the result, the location and anything you could not test.

This checklist is for landlords, letting agents and inventory clerks testing alarms on the first day of a tenancy in England. It is part of our inventory checklist guide. Our separate guide on the smoke and carbon monoxide alarm rules covers the law in full; this one is the practical test on the day. Wales and Scotland have their own rules.

What does the law require on the first day of a tenancy?

Under regulation 4 of the Smoke and Carbon Monoxide Alarm (England) Regulations 2015, as amended in 2022, a landlord must make sure that checks are made, by them or on their behalf, that each required alarm is in proper working order on the day a new tenancy begins. The required alarms are a smoke alarm on each storey with a room used as living accommodation, and a carbon monoxide alarm in any room used as living accommodation that has a fixed combustion appliance other than a gas cooker. A local authority can impose a penalty of up to £5,000 for a breach.

What should an alarm test checklist cover?

On the day the tenancy begins, work through every floor:

  • First, find every alarm on every storey, including basements and loft rooms that are lived in.
  • Then, confirm there is at least one smoke alarm on each of those storeys.
  • Find every fixed combustion appliance, such as a gas boiler, wood burner or open fire, and confirm a carbon monoxide alarm is in the same room.
  • Tell smoke, heat and carbon monoxide alarms apart; a heat alarm in a kitchen is common but is a different device from a smoke alarm.
  • Press and hold each test button until the alarm sounds, and record the result in plain words, such as “tested, power heard”.
  • Read the replacement or expiry date printed on the alarm, and record it, or record that it could not be seen.
  • Photograph each alarm so the date is legible.
  • Note any alarm that is missing, removed from its base, beeping, or past its date.
  • Where an alarm cannot be tested, such as one out of reach or a system run from a control panel, say so rather than recording a test.

What should happen if an alarm fails on the day?

If a required alarm is missing or fails on the day, the landlord or agent should be told straight away so it can be fitted or replaced before the tenant moves in. A faulty alarm on a storey that still has another working smoke alarm should still be recorded, because the tenant will rely on it.

What does an alarm test at check-in prove?

An alarm test at check-in proves that the alarm had power and sounded on the day it was tested. It does not prove the alarm is correctly sited, that an interlinked system works as a whole, or that the property meets every fire safety standard. A careful report states that limit rather than claiming more.

Record what you heard and saw, the date printed on the alarm, and anything you could not test.

Key takeaways

  • In England, required alarms must work on the day a new tenancy begins.
  • One smoke alarm per lived-in storey, and a CO alarm in any lived-in room with a fixed combustion appliance other than a gas cooker.
  • Test, photograph and record each alarm with its replacement date.
  • Say what could not be tested; never record a test that did not happen.

Where InventorySafe fits

InventorySafe is a UK property inventory service whose clerks capture photos, video and voice notes at every visit and sign every report. Every alarm is identified, tested, photographed and recorded by floor, any gap is flagged on the day, and our clerks can fit missing smoke or carbon monoxide alarms there and then for £50.

Common questions

Does a gas cooker need a carbon monoxide alarm in a rental?
Not under the rules in England. The regulations require a carbon monoxide alarm in rooms with a fixed combustion appliance other than a gas cooker, such as a gas boiler or a wood burner.
Who tests the alarms after the tenant moves in?
The landlord must make sure the alarms work on the day a new tenancy begins and must repair or replace one reported as faulty. During the tenancy, tenants are usually advised to test their alarms regularly and report any fault.
Does a smoke alarm in a bathroom count?
The regulations treat bathrooms as living accommodation, but smoke alarms are not normally fitted in bathrooms because steam sets them off. The smoke alarm for that storey is usually in a hallway or landing.
Should the alarm’s expiry date be in the inventory?
Yes. Alarms have a limited life, and a recorded replacement date shows when it is due. If the date cannot be read, the report should say so.

See a report from one of your own properties.

Book a demo, or tell us where your portfolio is and we’ll confirm clerk coverage.

Book a demo

Request a booking

We’ll confirm availability and the final price by email.

1The visit
Type of report
Property size
Extra spaces · garage, loft, cloakroom… £10 each
0
2The property

3Your details